Technical Specification:
- Flow Meter Size: 15 mm to 500 mm
- Measuring Range: 0.2 to 10 m/sec. Bidirectional
- Media: Conductive Liquid/Water, Slurry
- Required Electrical Conductivity: >10 uS/cm
- Operating Temperature: 0°C 60°C
Flow Sensor (Primary Head):
- Flow meter Measuring Principle: Faraday's law of Electromagnetic induction.
- Flow Meter Type: Full Bore Electromagnetic flow meter
- Coil Excitation Type: Pulsed DC
- Power Supply: 230 V AC, 50 Hz or 24 V DC
- Process Connections: Flange End
- Flange Pressure Rating: ASA 150
- Flange Material: CS/MS/SS
- Flow Sensor Pressure Rating: 10 kg/cm2 or as per Customer requirement
- Process Temperature: 70°C (for Rubber), 120°C (for PTFE)
- Lining Material: Rubber/PTFE
- Measuring Electrode Material: SS 316/Hastalloy C
- MOC of Flow Tube/Meter Tube: SS 304
- Sensor/Coil Housing (Shell): MS/SS 304/SS 316
- Protection Class for Sensor: IP 67, IP 68 (only with Remote Version)
Flow Converter (Transmitter):
- Type: Microprocessor based Integral/Remote Version
- Type of Display: 2 Line Backlit LCD display.
- Display Parameter: Instantaneous Flow, Total Flow with sum, forward and reverse total counters
- Measuring Accuracy: +/-0.5% of full scale reading
- Input: From flow Sensor
- Output: 4-20 mA, Pulse and MODBUS 485
- Enclosure MOC: Die Cast Aluminium
- Enclosure Protection Class: IP 65, IP 67
- Programming: Through push button
- Cable Entry: M20X15, Polyamide Cable Glands
- Communication Protocol: MODBUS RS 485 and HART (Optional)