Flow Measurement

Plastic Helical Flow Sensor & Meter

Helical rotor flow sensor specially for Liquid dispensing industries, now a day water dispensing industries use plastic turbine flow sensor its k factor change with flow rate so for solution we developer helical rotor plastic flow sensor with same pulse k factor for full range also provide very good accuracy and repeatability in full range of measurement.

Helical flow meters are positive displacement meters with a very favorable low pressure drop behavior. Therefore Perfectly suited for the flow measurement of very high viscosity fluids. Due to wide measuring ranges, high accuracy and resolution helical flow meters are an excellent choice for laminating systems, painting systems, adhesive dispense systems, as well as batching systems for various fluids.

Features : High accuracy
: Pressure: up to 25 bar
: Independent of viscosity, perfect for 1 to 106 mm²/s
: Low pressure drop compared with other positive displacement meters
: High resolution
: Pulsation-free measurement, non-sensitive to pulsating flows
: Resistant to corrosion by advanced materials and bearings

Applications : Polyurethane and polymer
: Light and heavy fuel oil
: Petrochemical products
: Thixotropical fluids
: Fat and oils with varying viscosities
: Test rigs with varying viscosities and fluids
: Water / glycol mixtures
: Crude oil, furnace oil, and all viscous liquid even viscosity change with Temperature
: Very good for WATER atm, water dipensing, tea/coffee/wine/juce and other food liquied measurement and dispensing,

 

S. S. Turbine Type Flow meter

Material of construction:
Rotor : S.S-304
Shaft : Hard Stainless Steel-316 with carbon bush
Accuracy (standard installation position) : +/- 0.5 or 1% FSD Repeatability : 0.1%
Maximum working pressure : 6 MPa
Fluid & Ambient temperature: -20 to 120 Deg. C
Connection: Thread (M/F) or flange

1) Pulse output sensor :
Power voltage: 12 V DC
Output signal: NPN open connector
Output:
high electric level : High than 8 VDC( input voltage 12 VDC)
low electric level : lower than 0.8 VDC( input voltage 12 VDC)

2) Battery operated meter :
Power voltage: 3.3 V10AH lithium batteries can be used more than 5 years in a row.
display mode:
Double row Liquid Crystal Display (LCD), as follows: L XXX. X four instantaneous flow (m3 / h) or L/h
XX. XXXXXX eight cumulative flow (m3) or L
Cumulative flow: automatically expand the display precision, the cumulative flow values can be reset.
Power-fail protection: instrument coefficient, the Total flow values ten years is not lost when power supply drop.

3) Display with 4 to 20 mA Output
Power voltage: 24 V
Output signal: 4 TO 20 mA

 

Diesel Flow Meter

Material of construction:
Enclosure : Aluminum anodize/S.S-304/S.S-316
Rotor : Aluminum anodize/S.S-316/PPS
O-ring : NBR/Viton
Shaft : Hard Stainless Steel-316
Accuracy (standard installation position) : ±1% RS /0.15% FSD
Repeatability : 0.1%
Maximum working pressure : 5 MPa for aluminum body
                                                     : 25 MPa for s.s. body
                                                     : above 250 bar please contact company
Fluid & Ambient temperature: -40 to80°C
Power voltage: Battery operated
Connection: Thread (M/F) or flange

1) Pulse output sensor :
Power voltage: 12 V DC
Output signal: NPN open connector
Output:
high electric level : High than 8 VDC( input voltage 12 VDC)
low electric level : lower than 0.8 VDC( input voltage 12 VDC)

2) Battery operated meter :
Power voltage: 3.3 V10AH lithium batteries can be used more than 5 years in a row.
display mode:
Double row Liquid Crystal Display (LCD), as follows: L XXX. X four instantaneous flow (m3 / h) or L/h
XX. XXXXXX eight cumulative flow (m3) or L
Cumulative flow: automatically expand the display precision, the cumulative flow values can be reset.
Power-fail protection: instrument coefficient, the Total flow values ten years is not lost when power supply drop.

3) Display with 4 to 20 mA Output
Power voltage: 24 V DC
Output signal: 4 TO 20 mA