Dew Point Meters
S211 Dew Point Sensor for Desiccant Dryers (-60… +20 °C Td)
Ideal dew point sensor to monitor desiccant dryers with a range of -60 … +20 °C Td.
- Accurate Dew point readings after desiccant dryers
- Integrated optional display for on-site values
- Integrated optional pressure sensor
- Precise measurement with ± 2 °C Td accuracy
- Flexible installation thanks to the compact design
- Compressed air quality monitoring of humidity
- 4 ... 20 mA 2-wire / 3-wire and Modbus/RTU
- Operating pressure of 0 ... 1.6 MPa (Optional 35.0 MPa)
S215 Dew Point Sensor for Fridge Dryers (-20… +50 °C Td)
Long term-stable dew point measurement in fridge dryer applications, with a range of -20 … +50 °C Td.
-
Reliable dew point monitoring after fridge dryers
-
Pressure sensor integrated as option for
-
Compressed air quality monitoring of humidity
-
Low maintenance costs due to stable measurements
-
Compact display for live readings at the sensor
-
Flexible installation due to the compact design
-
4 ... 20 mA 2-wire / 3-wire and Modbus/RTU
-
Operating pressure of 0 ... 1.6 MPa (Optional 35.0 MPa)
S220 Dew Point Sensor for Compressed Air (-100… +20 °C Td)
-
Dew point measurements in high-tech applications
-
Polymer + QCM dual-sensor for highest accuracy
-
Flexible installation thanks to the compact design
-
Low maintenance costs due to stable measurements
-
Pressure sensor for pressure depending humidity units
-
Display option for on-site readings or all values
-
4 ... 20 mA 2-wire / 3-wire and Modbus/RTU
-
Operating pressure of 0 ... 1.6 MPa (Optional 35.0 MPa)
S305 Dew Point Monitor for Desiccant and Fridge Dryers (-60… +20 °C Td / -20 … +50 °C Td)
Simple and cost-efficient dew point monitoring, by serving as a measuring and display device.
-
Plug & Play solution for easy installation and usage
-
Fast response time for time-efficient measurements
-
Precise measurement with ± 2 °C Td accuracy
-
Alarm indication with internal relays or alarm units
-
Easy process connection via 6 mm quick connect
-
-60 ... +50 °C Td depending on the model
-
4 … 20 mA signal output to PLC or SCADA system
-
Operating pressure of 0.3 ... 1.5 MPa
S520 Portable Dew Point Meter for Compressed Air and Gases (-100… +20 °C Td / -60… +50 °C Td)
Mobile and high reliable on-site dew point measurements in compressed air systems.
-
Flexible dew point meter for on-site live data
-
Measures dew point, temperature and pressure
-
Integrated data logger with mass storage
-
Smart device with camera for dew point prediction
-
Low dew point, down to -100 °C Td
-
Dew point audits according to ISO 8573-1
-
USB interface for data transfer or on-site print-outs
-
Operating pressure of -0.1 ... 1.5 MPa(g)