Dew Point Meters

S211 Dew Point Sensor for Desiccant Dryers (-60… +20 °C Td)

Ideal dew point sensor to monitor desiccant dryers with a range of -60 … +20 °C Td.

  • Accurate Dew point readings after desiccant dryers
  • Integrated optional display for on-site values
  • Integrated optional pressure sensor
  • Precise measurement with ± 2 °C Td accuracy
  • Flexible installation thanks to the compact design
  • Compressed air quality monitoring of humidity
  • 4 ... 20 mA 2-wire / 3-wire and Modbus/RTU
  • Operating pressure of 0 ... 1.6 MPa (Optional 35.0 MPa)
  •  

S215 Dew Point Sensor for Fridge Dryers (-20… +50 °C Td)

Long term-stable dew point measurement in fridge dryer applications, with a range of -20 … +50 °C Td.

  • Reliable dew point monitoring after fridge dryers

  • Pressure sensor integrated as option for

  • Compressed air quality monitoring of humidity

  • Low maintenance costs due to stable measurements

  • Compact display for live readings at the sensor

  • Flexible installation due to the compact design

  • 4 ... 20 mA 2-wire / 3-wire and Modbus/RTU

  • Operating pressure of 0 ... 1.6 MPa (Optional 35.0 MPa)

S220 Dew Point Sensor for Compressed Air (-100… +20 °C Td)

  • Dew point measurements in high-tech applications

  • Polymer + QCM dual-sensor for highest accuracy

  • Flexible installation thanks to the compact design

  • Low maintenance costs due to stable measurements

  • Pressure sensor for pressure depending humidity units

  • Display option for on-site readings or all values

  • 4 ... 20 mA 2-wire / 3-wire and Modbus/RTU

  • Operating pressure of 0 ... 1.6 MPa (Optional 35.0 MPa)

S305 Dew Point Monitor for Desiccant and Fridge Dryers (-60… +20 °C Td / -20 … +50 °C Td)

Simple and cost-efficient dew point monitoring, by serving as a measuring and display device.

  • Plug & Play solution for easy installation and usage

  • Fast response time for time-efficient measurements

  • Precise measurement with ± 2 °C Td accuracy

  • Alarm indication with internal relays or alarm units

  • Easy process connection via 6 mm quick connect

  • -60 ... +50 °C Td depending on the model

  • 4 … 20 mA signal output to PLC or SCADA system

  • Operating pressure of 0.3 ... 1.5 MPa

S520 Portable Dew Point Meter for Compressed Air and Gases (-100… +20 °C Td / -60… +50 °C Td)

Mobile and high reliable on-site dew point measurements in compressed air systems.

  • Flexible dew point meter for on-site live data

  • Measures dew point, temperature and pressure

  • Integrated data logger with mass storage

  • Smart device with camera for dew point prediction

  • Low dew point, down to -100 °C Td

  • Dew point audits according to ISO 8573-1

  • USB interface for data transfer or on-site print-outs

  • Operating pressure of -0.1 ... 1.5 MPa(g)